Transport gratuit la punctele de livrare Pick Up peste 299.00 lei
Packeta 15.00 lei Cargus 25.00 lei FAN 25.00 lei Easybox 20.00 lei

Aerodynamic and Thermal Design of Centrifugal Compressor

Limba englezăengleză
Carte Carte broșată
Carte Aerodynamic and Thermal Design of Centrifugal Compressor Samkit Shah
Codul Libristo: 18641157
Editura LAP Lambert Academic Publishing, noiembrie 2016
In the present study, a 3D numerical simulation of a non-dimensional design of impeller, diffuser an... Descrierea completă
? points 133 b
292.15 lei -9 %
263.77 lei
În depozitul extern Expediem în 9-11 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Profit Planning Peter Harris / Copertă tare
common.buy 1 306.80 lei
Karthyani's Hen Thomas George / Carte broșată
common.buy 57.51 lei
Craved Lola Smirnova / Carte broșată
common.buy 75.57 lei
Gene Regulatory Network Inference M. A. H. Akhand / Carte broșată
common.buy 235.82 lei
Barset Revisited Ronald McGowan / Carte broșată
common.buy 57.51 lei
A Thirty Year Journey Back to First Grade Nigel Davidoff / Carte broșată
common.buy 56.90 lei
Angel: Reversed Tricia Owens / Carte broșată
common.buy 88.89 lei
Hazards of Life and All That J Bond / Copertă tare
common.buy 1 306.80 lei
Le Commedie di Malandrino Franco Candido / Carte broșată
common.buy 48.23 lei
Study Guide for T. C. Boyle's Tortilla Curtain Cengage Learning Gale / Carte broșată
common.buy 62.46 lei

In the present study, a 3D numerical simulation of a non-dimensional design of impeller, diffuser and volute design of centrifugal compressor in dimensional form is carried out by using the commercial code of ANSYS R15.0. The fully 3D, Compressible and Steady flow analysis of the fluid (air) flow were solved in CFX solver. A SST k-v turbulent model was used for a simulation of the on-design performance of the single speed centrifugal compressor. By using this specific design results show that De-Haller number, non-dimensional mass flow rate, nondimensional ratio of axial length to exit diameter, divergence angle of Diffuser, area ratio from diffuser outlet to volute outlet obtained in order to 0.7, 0.092, 0.33, 7.29 and 0.65 respectively. Also, found that All Mach number are below 1 so there are no shock formations. The mass flow rate is less than chocking mass flow rate at the throat of impeller and diffuser so there is no choking of flow In order to verify the present numerical simulations, the model results were validated with the analytical method gives the good agreement but not exactly due to design losses were neglected.

Informații despre carte

Titlu complet Aerodynamic and Thermal Design of Centrifugal Compressor
Limba engleză
Legare Carte - Carte broșată
Data publicării 2017
Număr pagini 140
EAN 9786202017459
Codul Libristo 18641157
Greutatea 227
Dimensiuni 150 x 220 x 8
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo