Transport gratuit la punctele de livrare Pick Up peste 299.00 lei
Packeta 15.00 lei Cargus 25.00 lei FAN 25.00 lei Easybox 20.00 lei

Thermal Neutron Point Source Imaging Using a Rotating Modulation Collimator

Limba englezăengleză
Carte Carte broșată
Carte Thermal Neutron Point Source Imaging Using a Rotating Modulation Collimator Nathan O Boyce
Codul Libristo: 08142082
Editura Biblioscholar, octombrie 2012
This thesis demonstrates a previously untested capability of the Rotating Modulation Collimator (RMC... Descrierea completă
? points 150 b
297.88 lei
În depozitul extern Expediem în 15-20 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


This thesis demonstrates a previously untested capability of the Rotating Modulation Collimator (RMC) to image a point-like neutron source. The encouraging results, achieved using low-energy neutrons, provide motivation for further refinement and continued research with higher-energy neutrons. The detector and the masks on an existing RMC imaging system were exchanged to function with neutrons. The source in this research produced a poly-energetic spectrum of neutrons through the reaction. The source of alpha particles was a 72.7 mCi 239Pu source. The RMC detector was located 250 cm from the bare source and operated for three hours to generate a modulation profile: The number of particles detected at each rotation angle of the masks -- it is unique for each source location. The measured modulation profiles were used in a Maximum-Likelihood-Expectation-Maximization algorithm to reconstruct the images, and a Bootstrap resampling technique was used to determine uncertainty. The reconstructed images exhibited high contrast but low precision. The resampled image locations were widely distributed, but the most frequent value was very accurate. The uncertainty originated from an expectation model that did not account for fast neutron downscatter into the thermal neutron region as well as the fast neutrons streaming through the masks and being detected.

Informații despre carte

Titlu complet Thermal Neutron Point Source Imaging Using a Rotating Modulation Collimator
Limba engleză
Legare Carte - Carte broșată
Data publicării 2012
Număr pagini 106
EAN 9781249588214
ISBN 9781249588214
Codul Libristo 08142082
Editura Biblioscholar
Greutatea 204
Dimensiuni 189 x 246 x 6
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo